The YCB7-63N series miniature circuit breaker are suitable for overcurrent protection building line facilities and similar purposes in AC 50/60Hz, rated voltage 230V/400V, rated current up to 63A circuits. They have
isolation, overload, and short circuit protection functions, and can also be used for infrequent operation and switching of lines undernormal circumstances. Circuit breakers are suitable for various places such as
industry,commerce, high-rise buildings, and residential buildings.
Standard: IEC/EN 60898-1.
Manufacturing: Protect CNC machines, compressors, and conveyor systems.
Commercial Kitchens: Safeguard industrial ovens and refrigeration units.
HVAC Systems: Prevent overloads in high-capacity air handlers.
YCB7 | 63 | N | 1P | 16 | ||
Model | Shell grade current |
Breaking capacity |
Number of poles |
Tripping. characteristics |
Rated current | |
Miniature circuit breaker |
63 | N:6kA | 1P 2P 3P 4P |
B C D | 1 2 4 6 10 16 20 25 50 63 |
Note:This product can be assembled with accessories(YCB7-63N OF/SD/OF+SD/ MX/ MVMN/MX+OF, etc)
Type | Standard | IEC/EN 60898-1 | ||
Comprehensive data |
Function | Overload,Short circuit,Isolation | ||
Number of poles | 1P,2P,3P,4P | |||
Rated current In | A | 1-63A | ||
Rated frequency | Hz | 50/60Hz | ||
Electrical features |
Rated voltage Ue | V | 230/400 | |
Rated insulation voltage Ui | V | 500 | ||
Rated breaking capacity Icn | A | 6000 | ||
Rated impulse withstand voltage Uimp(1.2/50) | kA | 4 | ||
Pollution degree | 2 | |||
Use category | II、Ⅲ | |||
Trip type | Thermal magnetic release | |||
Thermal magnetic tripping characteristics | B,C,D | |||
Electrical and mechanical accessories | □ | |||
Mechanical features |
Mechanical life | Times | 20000 | |
Electrical life | Times | 10000 | ||
Protection degree | IP20 | |||
Antihumidity and heat resistance | The relative humidity of the air is not more than 50%when the ambient air temperature is +40℃,and it can have a higher relative humidity at a lower temperature |
|||
Reference ambient temperature | ℃ | 30 | ||
Ambient temperature | ℃ | -5°C-+40℃,the average value of 24h does not exceed+35℃ | ||
Height | m | Not exceeding 2000 | ||
Installation | Terminal connection type | Cable/Pin-type busbar | ||
Maximum wire capacity |
Terminal size top/bottom for cable |
mm² | 25 | |
AWG | 18-3 | |||
Terminal size top/bottom for busbar |
mm² | 25 | ||
AWG | 18-3 | |||
Torque | N*m | 2 | ||
In-Ibs | 18 | |||
Tool | 18 | Phillips screwdriver or flat-blade screwdriver | ||
Installation | On DIN rail EN 60715(35mm)by means of fast clip device | |||
Wiring method | From top or bottom |
Type | Test current | Tripping time | Expected result | Type | Test current | Tripping time | Expected result | |
B,C,D | 1.13In | t≤1h(In≤63A) | Not tripping | B | 3In | t≤0.1s | Not tripping | |
1.13In | t≤2h(In>63A) | C | 5In | t≤0.1s | ||||
B,C,D | 1.45In | t<1h(In≤63A) | Tripping | D | 10ln | t≤0.1s | ||
1.45In | t<2h(In>63A) | B | 5In | t<0.1s | Tripping | |||
B,C,D | 2.55In | 1sTripping |
|
C |
10ln |
t<0.1s |
| |
2.55In | 1s |
D | 20In | t<0.1s |
At a bustling small manufacturing plant in Chicago, managers prided themselves on meeting tight production deadlines. But behind the scenes, their aging electrical panels were a ticking time bomb.
The facility’s old circuit breakers frequently tripped during peak hours, halting assembly lines. Workers faced downtime, and repairs cost $5,000 monthly. Worse, a near-miss electrical fire revealed hidden risks.
“Every outage meant lost orders,” recalls the plant manager. “But upgrading the entire system was too expensive. We needed a fix that worked now.”
An audit exposed the root cause: single-pole MCBs couldn’t handle fluctuating loads. The team realized they needed dual protection for both live and neutral lines.
They installed the YCB7-63N 40A Double Pole MCB. With thermal-magnetic tripping and 20,000-cycle durability, it stopped overloads without nuisance trips.
Downtime reduced by 90% in 3 months.
$48,000 saved annually on repairs and lost productivity.
Zero safety incidents since installation.