Standard: IEC 60947-1, IEC 60947-4-1.
Rated operation current(Ie): 6-16A;
Rated operation voltage(Ue): 220V~690V;
Rated insulation voltage: 690V;
Poles: 3P、4P;
Installation: Din rail and screw installation
| Type | Operating and Installation Conditions |
| Installation category | III |
| Pollution level | 3 |
| Certification | CE, CB, CCC, TUV |
| Protection degree | Ip20 |
| Ambient temperature | limit of temperature: -35℃~+70℃,normal temperature: -5℃~+40℃,The average no more than +35℃ within 24 hours.If not in normal operating temperature range, please refer to "Instructions for abnormal environment" |
| Altitude | ≤2000m |
| Ambient temperature | The maximum temperature of 70 degrees, the air relative humidity not exceed 50%, under lowertemperature can allow for higher relative humidity.If the temperature is 20℃, the air relative humiditycould up to 90%, Special measures should betakenfor occasional condensation dueto humidity changes. |
| Installation position | Inclination between installation surface and vertical surface should not exceed ±5° |
| Shock vibration | Products should be installed and used withoutsignificant shake, shock and vibration place. |
|
Appearance |
||||
| Type | CJX2s-M06 | CJX2s-M09 | CJX2s-M12 | CJX2s-M16 |
| Poles | 3P/4P | |||||
| Rated insulation voltage(Ui) | V | 690 | ||||
| Rated operating voltage(Ue) | V | 380/400, 660/690 | ||||
| Rated thermal current(Ith) ,AC-1 | 20 | |||||
| Ratedoperation current(Ie) | AC-3,380/400V | A | 6 | 9 | 12 | 16 |
| AC-3,660/690V | A | 3.8 | 4.9 | 4.9 | 4.9 | |
| AC-4,380/400V | A | 6 | 9 | 9 | 12 | |
| AC-4,660/690V | A | 3.8 | 4.9 | 4.9 | 4.9 | |
| Rated operational power(Pe) | AC-3,380/400V | kW | 2.2 | 4 | 5.5 | 7.5 |
| AC-3,660/690V | kW | 3 | 4 | 4 | 4 | |
| Mechanical life | 10000 times | 1200 | ||||
| Electrical life | AC-3 | 120 | ||||
| AC-4 | See electrical life curve | |||||
| Frequencyof operation | AC-3 | times/ hour | 1200 | |||
| AC-4 | 300 | |||||
| Flexible wire | 1 wire mm² | 1…4 | ||
| No terminal | 2 wire | mm² | 1…4 | |
| Flexible wire | 1 wire | mm² | 1…4 | |
| With terminals | 2 wire | mm² | 1…2.5 | |
| Hard wire | 1 wire | mm² | 1…4 | |
| No terminal | 2 wire | mm² | 1…4 | |
| Fastening torque | N·m | 1.2 | ||
| Coil | ||||
| Rated control voltage(Us) | 50Hz | V | 24、36、48、110、127、220、380、415 | |
| 50/60Hz | V | 24、36、48、110、127、220、380、415 | ||
| DC | V | 12、24、36、48、110、127、220 | ||
| Allowed control circuit voltage(Us) | Operation | V | Installation inclination angle ±22.5°: 85%~110%Us; Installation inclination angle±5°: 70%~120% | |
| Release(AC) | V | Installation inclination angle ±22.5°: 20%~75%Us;Installation inclination angle±5°: 20%~60% | ||
| Release(DC) | V | Installation inclination angle ±22.5°: 10%~75%Us;Installation inclination angle±5°: 10%~60% | ||
| Power consumption of coil | Actuation | VA | 20-40 | |
| Keep | VA | 9.5 | ||
|
Consumption |
W | 1-3 | ||
| Auxiliary contacts specification | A | 1NO/1NC | |
| Rated thermal current (Ith) | A | 10 | |
| Rated operating voltage (Ue) | AC | V | 380/400 |
| DC | V | 220 | |
| Rated control capacit | AC-15 | VA | Ue/Ie: AC380V/400V/ 1. 5A It h: 10A |
| DC-13 | W | Ue/Ie: DC220V/0. 3A | |
| Type | Amax | Bmax | Cmax | Dmax | a | b | Φ |
| CJX2s-M06-M16 | 45.5 | 59 | 58 | 94 | 35±0.35 | 50±0.48 | 4.2 |
|
CJX2s-M06/Z-M16/Z |
45.5 | 59 | 70 | 106 | 35±0.35 | 50±0.48 | 4.2 |
| Type | Amax | Bmax | Cmax | Dmax | a | b | Φ |
| CJX2s-M06/N-M16/N | 91 | 59 | 58 | 94 | 80±0.35 | 50±0.48 | 4.2 |
| CJX2s-M06/Z/N-M16/Z/N | 91 | 59 | 70 | 106 | 35±0.35 | 50±0.48 | 4.2 |
| Motor power kW | Maximum operation current A | Number of contacts contained in the contactor body | Contactor model | ||
| 380V/400V | 660V/690V | (AC-3 380V/400V) | NO | NC | |
| 2.2 | 3 | 6 | 1 | 0 | CJX2s-M0610 |
| 2.2 | 3 | 6 | 0 | 1 | CJX2s-M0601 |
| 2.2 | 3 | 6 | 0 | 0 | CJX2s-M0604 |
| 2.2 | 3 | 6 | 0 | 0 | CJX2s-M0608 |
| 4 | 4 | 9 | 1 | 0 | CJX2s-M0910 |
| 4 | 4 | 9 | 0 | 1 | CJX2s-M0901 |
| 4 | 4 | 9 | 0 | 0 | CJX2s-M0904 |
| 4 | 4 | 9 | 0 | 0 | CJX2s-M0908 |
| 5.5 | 4 | 12 | 1 | 0 | CJX2s-M1210 |
| 5.5 | 4 | 12 | 0 | 1 | CJX2s-M1201 |
| 5.5 | 4 | 12 | 0 | 0 | CJX2s-M1204 |
| 5.5 | 4 | 12 | 0 | 0 | CJX2s-M1208 |
| 7.5 | 4 | 16 | 1 | 0 | CJX2s-M1610 |
| 7.5 | 4 | 16 | 0 | 1 | CJX2s-M1601 |
| 7.5 | 4 | 16 | 0 | 0 | CJX2s-M1604 |
| 7.5 | 4 | 16 | 0 | 0 | CJX2s-M1608 |
| AC(V) 50Hz | 24 | 36 | 48 | 110 | 127 | 220 | 380 | 415 |
| AC(V) 60Hz | 24 | 36 | 48 | 110 | 127 | 220 | 380 | 415 |
| AC(V) 50/60Hz | 24 | 36 | 48 | 110 | 127 | 220 | 380 | 415 |
| DC(V) | 12 | 24 | 36 | 48 | 110 | 127 | 220 | - |
| Altitude (m) | 2000 | 3000 | 4000 |
| Rated impulse withstand voltage correction factor | 1 | 0.88 | 0.78 |
| Rated operation current correction factor | 1 | 0.92 |
| Ambient temperature (℃) | 55 | 60 | 65 | 70 |
| Correction factor | 1 | 0.93 | 0.875 | 0.75 |