Wide Compatibility: Ideal for 3-phase systems (230V/400V) in factories, workshops, and high-rise buildings.
Adjustable Trip Curves: Choose B, C, or D curves for tailored protection of motors, transformers, or lighting circuits.
Extended Lifespan: 20,000 mechanical cycles and 10,000 electrical operations for long-term reliability.
Temperature Resilience: Stable performance in environments from -5°C to +40°C (see temperature derating table).
DIN Rail Mounting: Quick clip-on installation compatible with standard 35mm DIN rails (EN 60715).
Clear Status Indicators: Ergonomically designed handle for smooth operation and visual feedback.
YCB7 | - | 63 | N | 1P | C | 16 |
Model | Shell grade current | Breaking capacity | Number of poles | Tripping characteristics |
Rated curren | |
Miniatur circuit breaker e |
63 | N:6kA | 1P 2P 3P 4P |
B C D |
1 2 4 6 10 16 20 25 32 40 50 63 80 |
Note:This product can be assembled with accessories(YCB7-63N OF/SD/OF+SD/ MX/ MVMN/MX+OF, etc)
Type | Standard | IEC/EN 60898-1 | ||
Comprehensive data | Function | Overload, Short circuit, Isolation | ||
Number of poles | 1P,2P,3P,4P | |||
Rated current In | A | 1-63A | ||
Rated frequency | Hz | 50/60Hz | ||
Electrical features | Rated voltage Ue | V | 230/400 | |
Rated insulation voltage Ui | V | 500 | ||
Rated breaking capacity Icn | A | 6000 | ||
Rated impulse withstand voltage Uimp(1.2/50) | kA | 4 | ||
Pollution degree | 2 | |||
Use category | II、III | |||
Trip type | Thermal magnetic release | |||
Thermal magnetic tripping characteristics | B,C,D | |||
Electrical and mechanical accessories | 口 | |||
Mechanical features | Mechanical life | Times | 20000 | |
Electrical life | Times | 10000 | ||
Protection degree | IP20 | |||
Antihumidity and heat resistance | The relative humidity of the air is not more than 50% when the ambient air temperature is +40°C, and it can have a higher relative humidity at a lower temperature | |||
Reference ambient temperature | °C | 30 | ||
Ambient temperature | °C | -5°C-+40°C, the average value of 24h does not exceed +35°C | ||
Height | m | Not exceeding 2000 | ||
Installation | Terminal connection type | Cable/Pin-type busbar | ||
Maximum wire capacity |
Terminal size | mm² | 25 | |
top/bottom for cable | AWG | 18-3 | ||
Terminal size | mm² | 25 | ||
top/bottom for busbar | AWG | 18-3 | ||
Torque | N*m | 2 | ||
In-lbs | 18 | |||
Tool | 18 | Phillips screwdriver or flat-blade screwdriver | ||
Installation | On DIN rail EN 60715 (35mm) by means of fast clip device | |||
Wiring method | From top or bottom |
Industrial Equipment: Protect motors, compressors, and CNC machines.
Commercial Buildings: Safeguard HVAC systems, elevators, and lighting panels.
Residential Use: Ideal for high-power appliances in apartments or villas.
Cost-Effective Safety: Competitive 3 pole MCB 63A price for premium-grade protection.
Future-Proof Flexibility: Adjustable trip curves and wide current range (1A–63A).
Global Trust: Meets IEC/EN standards, ensuring compliance and reliability worldwide.
Type | Test current | Tripping time | Expected result | Type | Test current | Tripping time | Expected result | |
B,C,D | 1.13In | t≤1h(In≤63A) | Not tripping | B | 3In | t≤0.1s | Not tripping | |
1.13In | t≤2h(In>63A) | C | 5In | t≤0.1s | ||||
B,C,D | 1.45In | t<1h(In≤63A) | Tripping | D | 10In | t≤0.1s | ||
1.45In | t<2h(In>63A) | B | 5In | t<0.1s | Tripping | |||
B,C,D | 2.55In | 1s<t<60s(In≤32A) | Tripping | C | 10In | t<0.1s | ||
2.55In | 1s<t<120s(In>32A) | D | 20In | t<0.1s |
Q: What’s the difference between B, C, and D curves?
A:
B Curve: For resistive loads (lighting, sockets).
C Curve: For moderate inrush currents (motors, transformers).
D Curve: For high inrush currents (industrial machinery).
Q: Can this MCB handle voltage fluctuations?
A: Yes! Its 6000A breaking capacity ensures stability even during severe short circuits.
Q: Is it suitable for residential 3-phase systems?