Classification | Terminal markings | Terminal name | Function Description |
Contact out put(assive) |
12 | Start to the topNo delay inputOut (closed) |
The built-in bypass soft starter of YCQR8 series is adapted for power ranging |
34 | Initiate a mission Lingshi (closed) |
Supports multiple starting methods,including current-limiting start and voltage ramp start.It is also capable of applying programmable jog start andstart current limiting under each method. |
|
56 | Fault occurs Time(closed) | Equipped with various protection functions,including overcurrent protection, input/output phase loss protection,thyristor short-circuit protection,overheat protection,leakage detection,electronic thermal overload protection,etc. |
|
Contact input(Active) |
7 | Instantaneous stop input | Some built-in bypass soft starters support MODBUS-RTU communication, allowing connection with up to 32 devices,and enabling automatic communication through setting baud rate and communication address. |
8 | Soft stop input | The built-in bypass soft starter features adaptive power frequency for 50/60Hz. | |
9 | Start Input | Supports multiple starting methods,including current-limiting start and voltage ramp start.It is also capable of applying programmable jog start and start current limiting under each method. |
|
10 | Public end | Equipped with various protection functions,including overcurrent protection, input/output phase loss protection,thyristor short-circuit protection,overheat protection,leakage detection,electronic thermal overload protection,etc. |
|
Analog quantity output |
1,112 | Analog output | 11,12 can measure the current signal that changes with the load,output 4-20mA, or 0-20mA optional,calibrationValue 100,calculation formula:D=16(lx-4). Where Ixis the actual16measured current value (mA),and D is the motorLoad current(%)(can also be understoodas the rated current corresponding to the soft start setting of 20mA) |
DCvoltage output |
13(24V+)10(COM) | Can carry a 0.2A DC load,with 13(24V+)as the positive pole of thepower supply and 10(COM)as the negative pole of the power supply |
|
485 communi- cation |
1,415 | Pleaserefer to 485 communication protocol for details |
Model number | W1 | H1 | D |
YCQR8-22KW-37KWAC220V | 150 | 285 | 195 |
YCQR8-45KW-55KWAC220V | 210 | 370 | 240 |
YCQR8-75KW-115KWAC220V | 260 | 540 | 255 |
YCQR8-132KW-160KWAC220V | 300 | 635 | 275 |
YCQR8-185KW-220KWAC220V | 400 | 730 | 295 |
YCQR8-22KW-75KWAC380V | 150 | 285 | 195 |
YCQR8-90KW-115KWAC380V | 210 | 370 | 240 |
YCQR8-132KW-220KWAC380V | 260 | 540 | 255 |
YCQR8-250KW-350KWAC380V | 300 | 635 | 275 |
YCQR8-400KW-500KWAC380V | 400 | 730 | 295 |