Digital Meter

Technical data

  Technical parameters Index
Input Voltage Rated value AC 0~600V
Over load Consistent: 1.2 times  instantaneous: 2 times/30s
Comsumption <0.5VA (each phase)
Impedance >500kΩ
Current Rated value AC 1A, 5A
Over load Consistent: 1.2 times  instantaneous: 2times/1s
Impedance <2mΩ
Frequency 45~65Hz
Measuring
accuracy
Voltage, current ±(0.5%FS+one digit)
Active reactive power ±(0.5%FS+one digit)
Frequency ±0.1Hz
Harmonic The three-phase voltage/current 21 total harmonic content
Power factor ±0.01PF
Active energy ±0.5%(only for reference, not for meterage)
Reactive energy ±1.0%(only for reference, not for meterage)
Power Scope AC 220V, 50/60Hz    AC/DC 85~265V ......
Consumption <5VA
Safety Withstand
voltage
Input and power >2kV50Hz/1min
Input and output >1kV50Hz/1min
Output and power >2kV50Hz/1min
Insulating resistance Any two of input, output, power, casing >20MΩ
Environment Temperature Operation: -10~50℃
Storage: -25~70℃
Humidity ≤85%RH, free of wet and corrosive gas
Elevation ≤3000m

1. Technical data

Measuring range:
Digital AC Ammeter:Direct measurement:AC 0~5A;Accessory device:AC 0~9999A(CT */ 5A).
Digital DC Ammeter: Direct measurement:DC 0~5A;Accessory device :DC 0~9999A(Shunt */ 75mV).
Digital AC Voltmeter:Direct measurement:AC 0~600V;Accessory device:AC 0~9999KV(PT */ 100V)
Digital DC Voltmeter:Direct measurement:DC 0~600V
Digital Frequency Meter: 30.00~99.99Hz(AC 30~500V)
Accuracy rating: ±0.5 % FS±1 digit.
Measuring display mode: RMS measurement, four-digit LED nixietube display.
Auxiliary power supply: AC 220V,50/60Hz(Can customize other values:DC 24V,DC 48V,AC/DC 85~265V).

2. Terminal arrangement

Attention: If it is not the same with the wiring schema of diagram behind case, please refer to the diagram behind the case.

1. Technical data

Measuring range:
Digital Power Factor Meter:0.000C~0.500C~1.000~0.500L~0.000L.
Digital Active Power Meter: 0~999W~999KW~9999MW.
Signal input: Voltage:AC 0~500V(PT */ 100V),Current:AC 5A (CT */ 5A or 1A).
Accuracy rating :±0.5 % FS±1 digit.
Measuring display mode: RMS measurement, four-digit LED nixietube display.
Auxiliary power supply: AC 220V,50/60Hz(Can customize other values:DC 24V,DC 48V,AC/DC 85~265V).

2. Terminal arrangement

Attention: If it is not the same with the wiring schema of diagram behind case, please refer to the diagram behind the case.

1. Technical data

Measuring range:
Three Phase Digital Ammeter:Direct measurement:AC 0~5A;Accessory device:AC 0~9999A(CT */ 5A).
Three Phase Digital Voltmeter:Direct measurement:AC 0~600V;Accessory device:AC 0~9999KV(PT */ 100V)
Accuracy rating :±0.5 % FS±1 digit.
Measuring display mode: RMS measurement, four-digit LED nixietube display.
Auxiliary power supply: AC 220V,50/60Hz(Can customize other values:DC 24V,DC 48V,AC/DC 85~265V).

2. Terminal arrangement

Attention:If it is not the same with the wiring schema of diagram behind case, please refer to the behind the case.

1. Technical data

Measuring range:
Voltage: AC 0~500V Current: AC 0~9999A Frequency:45~65Hz or Power Factor:0.0C~0.5C~1.0~0.5L~0.0L or Active Power:0~9999KW Accuracy rating :±0.5 % FS±1 digit.
Measuring display mode: RMS measurement, four-digit LED nixietube display.
Auxiliary power supply: AC 220V,50/60Hz(Can customize other values:DC 24V,DC 48V,AC/DC 85~265V).

2. Terminal arrangement

Attention:If it is not the same with the wiring schema of diagram behind case, please refer to the behind the case.

3. Model and Specification

         Function
&Shape

Model

Measure &Display Shape Code(Figure Inside□) Selected Additional Functions
Current Voltage Frequency Power
Factor
Active
Power
96×96

80×80

72×72 48×48 Communication

interface:RS485

2-channels
switch output
1-channels
analog output
YC-□ K2-UI       V            
YC-□ K3-UIF     1/
V
y 1/
V
V      
YC-□ K3-UIH          
YC-□ K3-UIP          
YC-□    K3-UIF+RS          
YC-□    K3-UIH+RS          
YC-□    K3-UIP+RS          
YC-□     K3-UIF+2DO              
YC-□     K3-UIH+2DO              
YC-□     K3-UIP+2DO              
YC-□    K3-UIF+1AO              
YC-□     K3-UIH+1AO              
YC-□     K3-UIP+1AO              

1. Technical data

Measuring range:
● Phase voltage(UA UB UC) 0~500V ●Line voltage(UAB UBC UCA) 0~500V ●Current(IA IB IC) 0~9999A
● Freuqency or Freuqency&Power Factor or Active Power.
Signal input: Voltage:AC 0~500V(PT */ 100V),Current:AC 5A (CT */ 5A )
Accuracy rating :±0.5 % FS±1 digit.
Measuring display mode: RMS measurement, four-digit LED nixietube display.
Auxiliary power supply: AC 220V,50/60Hz(Can customize other values:AC/DC 85~265V).

2. Terminal arrangement

Attention:If it is not the same with the wiring schema of diagram behind case, please refer to the behind the case.

YC series  96×96

YC series  96×963. Model and Specification

             Function
&ShapeModel
Measure &Display Shape Code
(Figure  Inside□)
Selected Additional Functions
Phase
Voltage
Line
Voltage
Current Frequency Power
Factor
Active
Power
96×96 Communicationinterface:RS485 4-channels
switch output
YC-9K5-3UIF        
YC-9K5-3UIHF      
YC-9K5-3UIP        
YC-9 K6-3UI          
YC-9K5-3UIF+RS      
YC-9K5-3UIHF+RS    
YC-9K5-3UIP+RS      
YC-9K6-3UI+RS        
YC-9K5-3UIF+4DO      
YC-9K5-3UIHF+4DO    
YC-9K5-3UIP+4DO      
YC-9K6-3UI+4DO        

1. Technical data

Measuring range:
● Phase voltage(UA,UB,UC):0~500V ●Line voltage(UAB,UBC,UCA): 0~500V
●Current(IA,IB,IC): 0~9999A ●Freuqency: 45~65Hz
● Power factor(PFA,PFB,PFC,PFS) : 0.0C~1.0~0.0L ●Active power(PA,PB,PC,PS): 0~999W~999KW~9999MW
● Reactive power(QA,QB,QC,QS): 0~999Var~999KVar~9999MVar ●Apparent power(SA,SB,SC,SS): 0~999VA~999KVA~9999MVA ●Active electric energy: 0~9999999KWh~9999999MWh ●Reactive electric energy: 0~9999999KVarh~9999999MVarh
Signal input: AC 0~500V(PT */ 100V),AC 5A (CT */ 5A ) Accuracy rating:±0.5 % FS±1 digit.
Communication interface:RS485 communication,MODBUS_RTU protocol. Measuring display mode: RMS measurement Auxiliary power supply: AC 220V,50/60Hz(Can customize other values:AC/DC 85~265V).

2. Terminal arrangement

Attentio:n:If it is not the same with the wiring schema of diagram behind case, please refer to the behind the case.

Model YC series installation dimension and terminal arrangement   Model YC series installation dimension and terminal arrangement
YC-9K1-I     YC-9K1-3P    
YC-9K1-U YC-9K5-3UIF
YC-9K1-F YC-9K5-3UIHF
YC-9K1-H YC-9K5-3UIP
YC-9K1-P YC-9K6-3UI
YC-9K3-3I YC-9S3-3E
YC-9K3-3U YC-9SY-3E
YC-9K3-UIF YC-9S5-3E
YC-8K1-I     YC-8K3-3I    
YC-8K3-3U
YC-8K1-U YC-8K3-UIF
YC-8K1-F YC-8S3-3E
YC-8K1-H YC-8SY-3E
YC-8K1-P YC-7K3-3I    
YC-7K1-I     YC-7K3-3U
YC-7K3-UIF
YC-7S3-3E
YC-7K1-U YC-7SY-3E
YC-7K1-F YC-4K1-I    
YC-7K1-H YC-4K1-U
YC-7K1-P YC-4K1-F
YC-5K1-I     YC-4K1-H
YC-5K1-U YC-4K1-P
YC-5K1-F YC-4K3-3I
YC-5K1-H YC-4K3-3U
YC-5K1-P YC-4K3-UIF

Installation method