Technical data

MODEL LRS-250-12 LRS-250- 15 LRS-250-24 LRS-250-36 LRS-250-48
OUTPUT DC VOLTAGE 12V 15V 24V 36V 48V
RATED CURRENT 20A 16A 10A 6.7A 5A
CURRENT RANGE 0 ~ 20A 0 ~ 16A 0 ~ 10A 0 ~ 6.7A 0 ~ 5A
RATED POWER 240W 240W 240W 241.2W 240W
RIPPLE & NOISE (max.)  Note.2 150mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p
VOLTAGE ADJ. RANGE 10.2 ~ 13.8V 13.5 ~ 18V 21.6 ~ 28.8V 32.4 ~ 39.6V 43.2 ~ 52.8V
VOLTAGE TOLERANCE  Note.3 ±1.5% ±1.0% ±1.0% ±1.0% ±1.0%
LINE REGULATION    Note.4 ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
LOAD REGULATION  Note.5 ±1.0% ±0.5% ±0.5% ±0.5% ±0.5%
SETUP, RISE TIME 1300ms, 50ms/230VAC 1300ms,50ms/115VAC at full load
HOLD UP TIME (Typ.) 16ms/230VAC 12ms/115VAC at full load
INPUT VOLTAGE RANGE 90 ~ 132VAC / 180 ~ 264VAC by switch 240 ~ 370VDC (switch on 230VAC)
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 87.50% 88% 89.50% 89.50% 90%
AC CURRENT (Typ.) 5.0A/115VAC   2.5A/230VAC
INRUSH CURRENT (Typ.) COLD STAR 60A/115VAC 60A/230VAC
LEAKAGE CURRENT <2mA / 240VAC
PROTECTION OVER LOAD 110 ~ 140% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENT WORKING TEMP. -20 ~ +70℃ ( Refer to "Derating Curve")
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)
VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC STANDARDS EN60950 - 1
WITHSTAND VOLTAGE I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
OTHERS MTBF 347.5K hrs min. MIL-HDBK-217F (25℃)
DIMENSION 215*115*30mm (L*W*H)
WEIGHT 0.66Kg