MODEL |
LRS-250-12 |
LRS-250- 15 |
LRS-250-24 |
LRS-250-36 |
LRS-250-48 |
OUTPUT |
DC VOLTAGE |
12V |
15V |
24V |
36V |
48V |
RATED CURRENT |
20A |
16A |
10A |
6.7A |
5A |
CURRENT RANGE |
0 ~ 20A |
0 ~ 16A |
0 ~ 10A |
0 ~ 6.7A |
0 ~ 5A |
RATED POWER |
240W |
240W |
240W |
241.2W |
240W |
RIPPLE & NOISE (max.) Note.2 |
150mVp-p |
150mVp-p |
150mVp-p |
200mVp-p |
200mVp-p |
VOLTAGE ADJ. RANGE |
10.2 ~ 13.8V |
13.5 ~ 18V |
21.6 ~ 28.8V |
32.4 ~ 39.6V |
43.2 ~ 52.8V |
VOLTAGE TOLERANCE Note.3 |
±1.5% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
LINE REGULATION Note.4 |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
LOAD REGULATION Note.5 |
±1.0% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
SETUP, RISE TIME |
1300ms, 50ms/230VAC 1300ms,50ms/115VAC at full load |
HOLD UP TIME (Typ.) |
16ms/230VAC 12ms/115VAC at full load |
INPUT |
VOLTAGE RANGE |
90 ~ 132VAC / 180 ~ 264VAC by switch 240 ~ 370VDC (switch on 230VAC) |
FREQUENCY RANGE |
47 ~ 63Hz |
EFFICIENCY (Typ.) |
87.50% |
88% |
89.50% |
89.50% |
90% |
AC CURRENT (Typ.) |
5.0A/115VAC 2.5A/230VAC |
INRUSH CURRENT (Typ.) |
COLD STAR 60A/115VAC 60A/230VAC |
LEAKAGE CURRENT |
<2mA / 240VAC |
PROTECTION |
OVER LOAD |
110 ~ 140% rated output power |
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
ENVIRONMENT |
WORKING TEMP. |
-20 ~ +70℃ ( Refer to "Derating Curve") |
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
STORAGE TEMP., HUMIDITY |
-40 ~ +85℃, 10 ~ 95% RH |
TEMP. COEFFICIENT |
±0.03%/℃ (0 ~ 50℃) |
VIBRATION |
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes |
SAFETY & EMC |
STANDARDS |
EN60950 - 1 |
WITHSTAND VOLTAGE |
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH |
OTHERS |
MTBF |
347.5K hrs min. MIL-HDBK-217F (25℃) |
DIMENSION |
215*115*30mm (L*W*H) |
WEIGHT |
0.66Kg |