MODEL |
LRS-35-12 |
LRS-35- 15 |
LRS-35-24 |
LRS-35-36 |
LRS-35-48 |
OUTPUT |
DC VOLTAGE |
12V |
15V |
24V |
36V |
48V |
RATED CURRENT |
3A |
2.4A |
1.5A |
1A |
0.8A |
CURRENT RANGE |
0 ~ 3A |
0 ~ 2.4A |
0 ~ 1.5A |
0 ~ 1A |
0 ~ 0.8A |
RATED POWER |
36W |
36W |
36W |
36W |
38.4W |
RIPPLE & NOISE (max.) Note.2 |
120mVp-p |
120mVp-p |
150mVp-p |
200mVp-p |
200mVp-p |
VOLTAGE ADJ. RANGE |
10.2 ~ 13.8V |
13.5 ~ 18V |
21.6 ~ 28.8V |
32.4 ~ 39.6V |
43.2 ~ 52.8V |
VOLTAGE TOLERANCE Note.3 |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
LINE REGULATION Note.4 |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
LOAD REGULATION Note.5 |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
SETUP, RISE TIME |
1000ms, 30ms/230VAC 2000ms,30ms/115VAC at full load |
HOLD UP TIME (Typ.) |
30ms/230VAC 12ms/115VAC at full load |
INPUT |
VOLTAGE RANGE |
85 ~ 264VAC 120 ~ 373VDC |
FREQUENCY RANGE |
47 ~ 63Hz |
EFFICIENCY (Typ.) |
86% |
86% |
88% |
88% |
89% |
AC CURRENT (Typ.) |
0.7A/115VAC 0.42A/230VAC |
INRUSH CURRENT (Typ.) |
COLD START 45A/230VAC |
LEAKAGE CURRENT |
<0.75mA / 240VAC |
PROTECTION |
OVER LOAD |
110 ~ 150% rated output power |
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
ENVIRONMENT |
WORKING TEMP. |
-20 ~ +70℃ ( Refer to "Derating Curve") |
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
STORAGE TEMP., HUMIDITY |
-40 ~ +85℃, 10 ~ 95% RH |
TEMP. COEFFICIENT |
±0.03%/℃ (0 ~ 50℃) |
SAFETY & EMC |
VIBRATION |
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes |
STANDARDS |
EN60950 - 1, EN60335 - 1, EN61558 - 1 2 16 |
WITHSTAND VOLTAGE |
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH |
OTHERS |
MTBF |
763.6K hrs min. MIL-HDBK-217F (25℃) |
DIMENSION |
99*82*30mm (L*W*H) |
WEIGHT |
0.23Kg |