SSR-H3100ZF
SSR-H3200ZF
* Remark: 1. When the load current is 10A, you must install the radiator. When it's 40A or above, you must use fan forced cooling or water cooling. 2. When using inductive load, please connect a varistor on the output terminal, its value should be 1.6-1.9 times of the load voltage.
SSR-H3100ZF
Item |
Data |
Load Voltage |
440VAC (Fundamental type), 660VAC (High voltage type) and 1200 (Enhanced type) |
Load Current |
80,100,120A |
Control Voltage |
90-250VAC or 3-32VDC |
Control Current |
AC≤12mA DC10mA |
On Voltage |
≤1.5V |
Off Leakage Current |
≤4mA |
On-off Time |
≤10mS |
Dielectric Strength |
2500VAC |
Insulation Resistance |
1000MΩ/500VDC |
Ambient Temperature |
-30~+75℃ |
Mounting Methods |
Bolted |
The work instructions |
LED |
SSR-H3200ZF
Item |
Data |
Load Voltage |
440VAC (Fundamental type), 660VAC (High voltage type) and 1200 (Enhanced type) |
Load Current |
150,200,250,290A |
Control Voltage |
90-250VAC or 3-32VDC |
Control Current |
AC≤12mA DC10mA |
On Voltage |
≤1.5V |
Off Leakage Current |
≤4mA |
On-off Time |
≤10mS |
Dielectric Strength |
2500VAC |
Insulation Resistance |
1000MΩ/500VDC |
Ambient Temperature |
-30~+75℃ |
Mounting Methods |
Bolted |
The work instructions |
LED |