| ltem |
Data |
| Product |
|
| Thermo-magnetic release characteristic |
C type(Other types can be customized) |
| Rated current In |
63A,100A |
| Rated short-circuit capacity Icn |
6kA |
| Short-circuit protection |
When there is short circuit fault,it can trip within 100ms |
| Leakage protection |
When there is leakage fault,it can trip within 100ms |
| Leakage protection value |
30~500mA can be set freely |
| The leakage self-inspection |
According to the actual use,can set the day,hour and minute |
| Over and under voltage protection |
When there is over or under voltage fault,it can trip after 3s(0~99s can be set); over-voltage set value:250~320V;under-voltage set value:100~200V |
| On-delay |
When there is power,the switch will be automatically closed,0~99s can be set |
| Rated current setting |
1A~1In |
| Overload delay protection |
0~99s can be set |
| Over temperature protection |
0~120℃ can be set,OFF-delay time 0~99s can be set |
| Under power |
The amount of load change can be set,OFF-delay time 0~99s can be set |
| Over power |
The amount of load change can be set,OFF-delay time 0~99s can be set |
| Power limit |
Reach limit power,OFF-delay time 3s,(0~99s can be set) |
| Timing control |
5 groups of times can be set |
| Imbalance |
Percentage can be set for both voltage and current,OFF-delay time 0~99s can be set |
| Record |
Locally queried 680 switch event logs |
| Display |
Chinese and English Menu |
| Operation times |
Record various operation times of circuit breaker to determine whether the circuit breaker is within ts effective life |
| Maintain |
Set self check,device reset,power reset,record reset,synchronize clock,restart device, restore system default,etc |
| Check |
Local view of voltage,current,leakage current,temperature,active power,reactive power, apparent power,power factor,cumulative electricity,daily electricity (view 7-day record) |
| Manual automatic integrated control |
Mobile phone APP or PC control,can be controlled by the button, can also be controlled through the handle |
| Cover plate,pull rod |
It has the function of preventing electricity-stolen,maintenance and overhauls dosed by mistake. |
| Communication mode |
RS485 standard;4G,WIFI,NB,RJ45 optional |
| Remote Software Upgrade |
According to the actual situation,customized procedures to achieve remote update and upgrade |
The following functions can be set to open,close,alarm or trip functions |
overvoltage protection,undervoltage protection,overload protection,automatic closing, power off protection,remote control,open cover protection,under load protection,over power protection,under power protection,early warning function,timing self -check, warning allowed,gear return,high temperature protection,timing control,open phase protection,fault phase protection,voltage imbalance,current imbalance |