YCQ9 series automatic transfer switch is suitable for AC 50Hz, rated working voltage
AC400V, rated operating current up to 630A three-phase four-wire dual-circuit
power supply grid, automatically connect one or several load circuits from one
power supply to another to ensure load normal power supply of the circuit. This
product is suitable for industrial, commercial, high-rise and residential buildings,
etc.more important places.
Standard: IEC 60947-6
1.Full range of dual-input single-output(up in and down out),convenient wiring and cost-saving.
2.Handle front operation for convenience and labor-saving
3.Compact size for space saving
4.Two controllers to meet different user needs
5.Low main circuit impedance and energy consumption
6.Reliable double interlock protection function
7.Instantaneous structural design, cleverly driven by dual springs, with a simple and stable structure
8.Rotary contact structure, circular arc extinguishing device design, good arc extinguishing performance, and long contact working life
●Control voltage: switch control voltage level is 230V
●Position indication: Indicates the position of the switch working state (I, O, II)
●Main body of the switch: the front part is the Ⅰ road, which is connected to the "normal power supply"; the rear part is the Ⅱ road,
which is connected to the “standby power supply”
YCQ9 | 63 | 3 | A | 16A | FFD |
Model | Shell frame | Number of poles | Controller type | Rated current | Function |
Automatic transfer switch(PC cass) |
63(16~63A) | 2:2P 3:3P 4:4P |
A: Economy |
16A 20A 25A 32A 40A 50A 63A 80A 100A 125A 160A 200A 225A 250A 315A 350A 400A 450A 500A 630A |
|
125(50~125A) | B: Standard |
/:Fire control linkageFF:Fire feedbackD:GeneratorFFD:Fire feedback, Generator |
|||
250(125~250A) | |||||
630(250~630A) |
Model | YCQ9-63 | YCQ9-125 | YCQ9-250 | YCQ9-630 |
Function | Isolation, switch | |||
Structure | Integrated | |||
Electric equipment level | PC class | |||
Utilization category | AC-33B | |||
Number of poles | 2P、 3P、4P |
Rated insulation voltage Ui(V) | AC800 | AC1000 | |||
Rated operating voltage Ue (V) | AC400(2P product AC230) | AC415 | |||
Rated current Ie(A) | 16,20,25,32,40,50,63 | 50,63,80,100,125 | 125,160,200,225,250 | 250,315,350,400,450,000,000 | |
Rated operating frequency (Hz) | 50 | ||||
Rated impulse withstand voltage Uimp (kV) | 8 | 12 | |||
Rated impulse withstand current Icw(kA) | 5/30ms | 10/30ms | 25/1ms | ||
Rated short-circuit making capacity Icm(kA) |
8 | 17 | 52.5 | ||
Contact transfer time(s) | 0.6±20% | ||||
Operating transfer time(s) | 1.3±10% | ||||
Return time(s) | 1.3±10% | ||||
Power outage time(s) | 0.6±20% | ||||
Operation method | Auto/Manual | ||||
Switch position | Normal(I)、Power outage(O)、Standby(II) | ||||
Mechanical endurance (times) | 8000(*) | 4000( *) | |||
Electrical endurance (times) | 2000(*) | 1000(*) | |||
Applicable environmental conditions and installation | |||||
Working temperature(℃) | -5~+40 | ||||
Altitude(m) | ≤2000 | ||||
Atmospheric conditions |
The relative humidity of the atmosphere shall not exceed 50% at the highest ambient temperature of +40 ℃. At lower temperatures, there can be higher relative humidity, such as reaching 90% at+20 ℃ . Special measures should betaken for occasional condensation caused by temperature changes; |
||||
Pollution degree | 3 | ||||
Installation environment | Places without obvious vibration and impact | ||||
EMC environment | Environment B | ||||
Protection degree | IP20 | ||||
Power supply voltage deviation range(V) | 160±10% | ||||
Normal working voltage range | 85%Ue~110%Ue | ||||
Installation | Vertical fixed installation | ||||
Wiring method | Screw wiring | ||||
Connection | Front connection | ||||
Maximum number of conductors allowed to be clamped in | 1 | 2 | |||
Maximum screw torque | 2.5 | 6 | 10 | 22 |
Parameters of controller
Type | Type A | Type B |
Power supply and opening/closing indication | ■ | ■ |
Automatically transfer and restore operation | ■ | ■ |
Grid-grid | ■ | ■ |
Grid-generator(start/stop) | - | □ |
Three-phase monitoring commonly used to detect phase loss in power supply | ■ | ■ |
Three-phase monitoring commonly used to detect power loss in power supply | ■ | ■ |
Single-phase monitoring commonly used to detect phase loss in power supply | ■ | ■ |
Single-phase monitoring commonly used to detect power loss in power supply | ■ | ■ |
Handle manual operation | ■ | ■ |
External wiring terminal of indicator light | ■ | ■ |
Fire control linkage(24VDC) | - | □ |
Fire feedback | - | □ |
Specifications | A | B | H | A1 | B1 | A2 | A3 | A4 | H1 | H2 | H3 | H4 | C | C1 | D | φX | ||||
2P | 3P | 4P | 2P | 3P | 4P | |||||||||||||||
63 | 171 | 193 | 215 | 138 | 68 | 44 | 66 | 88 | 106 | 136 | 22 | 13 | 152 | 52 | 24 | 43 | 2 | 13 | 5.2 | 6 |
125 | 229 | 259 | 289 | 136 | 102 | 214 | 244 | 274 | 100 | 162 | 30 | 15 | 240 | 77 | 35 | 62 | 4 | 21 | 7 | 6 |
250 | 302 | 347 | 393 | 170 | 128 | 283 | 328 | 374 | 125 | 207 | 45.5 | 25 | 257 | 96 | 44 | 79 | 4 | 22 | 9 | 8 |
630 | 460 | 528 | 596 | 255 | 192 | 433 | 501 | 569 | 188 | 325 | 68 | 49 | 367 | 144 | 65 | 118 | 6 | 40 | 13 | 120 |