Home Categories Send inquiry

YCW8-HU Air circuit breaker

General

YCW8HUseries air circuit breaker(hereinafter called ACB) is suitable for the circuit of AC 50Hz/60Hz with rated service voltage 

800V, 1140V and rated service current between 630A and 4000A. It is mainly used to distribute electric energy and protect 

circuits and electric equipment against over-load,  under-voltage, short-circuit and single-phase earthing fault.

With  intelligent  and  selective  protection  functions,  the  breaker  can  improve  the reliability  of  power  supply,  and  avoid  unnecessary  power  failure.  

The  breaker  is applicable for power stations, factories.

Standard: IEC 60947-2,IEC 60947-4-1

Type designation

YCW8

product name

 

4000

Shell

framecurrent

HU

Breaking Capacity

/

/

3

number of poles

2500A

Rated  current

D

Installation type

H

Connection

M

controller type

 

 

 

 

 

YCW8

 

 

 

 

 

2500(630~2500A)  4000(2000~4000A)

 

 

 

HU  : AC800   /1140V

 

 

 

 

 

/

 

 

 

 

3:3P 4:4P

630

800

1000

1250

1600

2000

2500

2900

3200

3600

3900

4000

 

 

 

 

D: Drawer style

F: Fixed

 

 

 

 

H: Horizontal wiring

V: Vertical wiring

 

 

 

 

M: LED display

3M: LCD display

3H: LCD display with communication

Operating conditions

Item

Description

Ambient temperature

-5℃~+40℃;the average value within 24h shall not exceed +35℃; L type and M type controller can be used under -40℃~+70℃

Altitude

≤2000m

Pollution grade

3

Safety category

Main circuit and undervoltage tripping coil is IV, other auxiliary and control circuit is III

Installation position

Vertically installed, inclination between the mounting plane and the vertical plane should not exceed ±5°

Technical data

Item

Description

Shell current Inm (A)

2500

4000

Rated working current In (A)

630,800,1000

1250,1600,2000,2500

2000, 2500, 2900,

3200, 3600, 3900, 4000

Rated working voltage Ue (V)

800/1140

Rated insulation voltage Ui (V)

1140

Rated impulse withstand voltage Uimp (KV)

12

Power frequency withstand voltage (V) for 1 minute

3500

Number of poles

3P,4P

Rated limit short breaking capacity Icu (KA)

800/1140V

50

50

Rated operating short-circuit breaking capacity Ics (KA)

800/1140V

50

50

Rated short time withstand current for 1s ICW (KA)

800/1140V

50

50

Full power interruption time (without additional delay) (ms)

12~18

Closing time (ms)

≤60

Electrical lifespan

2000

Mechanical life (maintenance free)

10000

Mechanical life (with maintenance)

20000

Basic and optional functions of the controller

Basic function

Optional function

Overload long delay, short circuit short delay, and short circuit instantaneous protection

Signal contact output

Functional testing

MCR and over limit tripping

Fault memory

Load monitoring

Thermal memory

Voltage measurement

Self diagnosis

 

Current measurement

 

Fault status indication and numerical display

 

Earth fault protection

 

Basic function

Optional function

Overload long delay, short circuit short delay, and short circuit instantaneous protection

Current imbalance protection

Functional testing

Signal contact output

Fault memory

MCR and over limit tripping

Thermal memory

Load monitoring

Self diagnosis

power measurement

Current measurement

Power factor measurement

Fault status indication and numerical display

Electric energy measurement

Communication function (3H)

Regional interlocking

Contact wear indicator (3H)

Harmonic measurement

Operation fault protection record (3H)

Voltage protection

Earth fault protection

Voltage measurement

 

 

Controller model

M

3M

3H

Overload long delay protection

 

 

 

Short circuit short time delay protection

 

 

 

Short circuit instantaneous protection

 

 

 

Earth fault protection

 

 

 

Current imbalance protection

 

 

 

Functional testing

 

 

 

Fault memory

 

 

 

Signal contact output

 

 

 

Thermal memory

 

 

 

Self diagnosis

 

 

 

MCU working instructions

 

 

 

Current column display

 

 

 

Current measurement

 

 

 

MCR and over limit tripping

 

 

 

Load monitoring

 

 

 

Fault status indication and numerical display

 

 

 

Voltage measurement

 

 

 

Power factor measurement

 

 

 

power measurement

 

 

 

Electric energy measurement

 

 

 

Communication function

 

 

 

Contact wear indication

 

 

 

Regional interlocking

 

 

 

Harmonic measurement

 

 

 

Voltage protection

 

 

 

Record of operation times

 

 

 

 

 
Accessories