General
YCW8HUseries air circuit breaker(hereinafter called ACB) is suitable for the circuit of AC 50Hz/60Hz with rated service voltage
800V, 1140V and rated service current between 630A and 4000A. It is mainly used to distribute electric energy and protect
circuits and electric equipment against over-load, under-voltage, short-circuit and single-phase earthing fault.
With intelligent and selective protection functions, the breaker can improve the reliability of power supply, and avoid unnecessary power failure.
The breaker is applicable for power stations, factories.
Standard: IEC 60947-2,IEC 60947-4-1
Type designation
YCW8 product name |
|
4000 Shell framecurrent |
HU Breaking Capacity |
/ / |
3 number of poles |
2500A Rated current |
D Installation type |
H Connection |
M controller type |
YCW8 |
|
2500(630~2500A) 4000(2000~4000A) |
HU : AC800 /1140V |
/ |
3:3P 4:4P |
630 800 1000 1250 1600 2000 2500 2900 3200 3600 3900 4000 |
D: Drawer style F: Fixed |
H: Horizontal wiring V: Vertical wiring |
M: LED display 3M: LCD display 3H: LCD display with communication |
Operating conditions
Item |
Description |
Ambient temperature |
-5℃~+40℃;the average value within 24h shall not exceed +35℃; L type and M type controller can be used under -40℃~+70℃ |
Altitude |
≤2000m |
Pollution grade |
3 |
Safety category |
Main circuit and undervoltage tripping coil is IV, other auxiliary and control circuit is III |
Installation position |
Vertically installed, inclination between the mounting plane and the vertical plane should not exceed ±5° |
Technical data
Item |
Description |
||
Shell current Inm (A) |
2500 |
4000 |
|
Rated working current In (A) |
630,800,1000 1250,1600,2000,2500 |
2000, 2500, 2900, 3200, 3600, 3900, 4000 |
|
Rated working voltage Ue (V) |
800/1140 |
||
Rated insulation voltage Ui (V) |
1140 |
||
Rated impulse withstand voltage Uimp (KV) |
12 |
||
Power frequency withstand voltage (V) for 1 minute |
3500 |
||
Number of poles |
3P,4P |
||
Rated limit short breaking capacity Icu (KA) |
800/1140V |
50 |
50 |
Rated operating short-circuit breaking capacity Ics (KA) |
800/1140V |
50 |
50 |
Rated short time withstand current for 1s ICW (KA) |
800/1140V |
50 |
50 |
Full power interruption time (without additional delay) (ms) |
12~18 |
||
Closing time (ms) |
≤60 |
||
Electrical lifespan |
2000 |
||
Mechanical life (maintenance free) |
10000 |
||
Mechanical life (with maintenance) |
20000 |
Basic and optional functions of the controller
Basic function |
Optional function |
Overload long delay, short circuit short delay, and short circuit instantaneous protection |
Signal contact output |
Functional testing |
MCR and over limit tripping |
Fault memory |
Load monitoring |
Thermal memory |
Voltage measurement |
Self diagnosis |
|
Current measurement |
|
Fault status indication and numerical display |
|
Earth fault protection |
Basic function |
Optional function |
Overload long delay, short circuit short delay, and short circuit instantaneous protection |
Current imbalance protection |
Functional testing |
Signal contact output |
Fault memory |
MCR and over limit tripping |
Thermal memory |
Load monitoring |
Self diagnosis |
power measurement |
Current measurement |
Power factor measurement |
Fault status indication and numerical display |
Electric energy measurement |
Communication function (3H) |
Regional interlocking |
Contact wear indicator (3H) |
Harmonic measurement |
Operation fault protection record (3H) |
Voltage protection |
Earth fault protection |
Voltage measurement |
Controller model |
M |
3M |
3H |
Overload long delay protection |
|
|
|
Short circuit short time delay protection |
|
|
|
Short circuit instantaneous protection |
|
|
|
Earth fault protection |
|
|
|
Current imbalance protection |
|
|
|
Functional testing |
|
|
|
Fault memory |
|
|
|
Signal contact output |
|
|
|
Thermal memory |
|
|
|
Self diagnosis |
|
|
|
MCU working instructions |
|
|
|
Current column display |
|
|
|
Current measurement |
|
|
|
MCR and over limit tripping |
|
|
|
Load monitoring |
|
|
|
Fault status indication and numerical display |
|
|
|
Voltage measurement |
|
|
|
Power factor measurement |
|
|
|
power measurement |
|
|
|
Electric energy measurement |
|
|
|
Communication function |
|
|
|
Contact wear indication |
|
|
|
Regional interlocking |
|
|
|
Harmonic measurement |
|
|
|
Voltage protection |
|
|
|
Record of operation times |
|
|
|
Accessories